Search results for "endovascular repair"

showing 10 items of 13 documents

Total occlusion of aortic arch in a 62-year-old man presenting with acute myocardial infarction

2011

Not available

Aortic archMalemedicine.medical_specialtyTiclopidineAortic DiseasesMyocardial Infarctionacute myocardial infarctionAorta ThoracicCoronary AngiographyTotal occlusionSettore MED/22 - Chirurgia Vascolaremedicine.arteryInternal medicinemedicineHumansaortic arch occlusionMyocardial infarctionAngioplasty Balloon CoronaryEnoxaparinbusiness.industryGeneral MedicineMiddle Agedmedicine.diseaseClopidogrelaortic arch occlusion myocardial infarction endovascular repair stent-graftCardiologyStentsCardiology and Cardiovascular MedicinebusinessTomography X-Ray Computedcomputed tomography angiography
researchProduct

Mortality of ruptured abdominal aortic aneurysm with selective use of endovascular repair

2009

The aim of this review was to examine the results over a seven-year period of treatment for ruptured abdominal aortic aneurysm (RAAA). From 2002 on, our tertiary referral centre offered both open and endovascular (EVAR) treatment modalities for RAAA. All patients with a proven RAAA who were admitted into our hospital were included. Primary outcome measure was surgical mortality. In total 261 patients were admitted with suspicion of acute AAA. Of these, 175 (67%) had a RAAA, confirmed by computed tomography-scanning or at laparotomy. One hundred and fifty-nine patients (90.9%) were treated, 114 by open repair and 45 by EVAR. Overall mortality of patients treated was 25.2%, with an open repai…

Blood Vessel Prosthesis ImplantationTime FactorsTreatment Outcomeabdominal aortic aneurysmsurgical mortalityAortic RuptureHemodynamicsHumansendovascular repairTomography X-Ray ComputedAortographySettore MED/22 - Chirurgia VascolareAortic Aneurysm Abdominal
researchProduct

Hybrid Endograft Solution for Complex Iliac Anatomy

2010

The purpose of this study was to evaluate single-center results with selective use of Gore Excluder limbs (W.L. Gore & Associates, Flagstaff, AZ) in a Cook Zenith body (Cook Inc, Bloomington, IN) for elective endovascular abdominal aortic aneurysm (AAA) repair. A prospectively held database for patients with AAA, who were treated endovascularly between March 1999 and July 2008, was queried for patients treated with a Cook Zenith body and one or two Gore Excluder limbs. Indication, technical success, late limb occlusion, and disconnection were evaluated. From 276 patients who were treated with a Zenith body, 29 underwent repair with hybrid graft components with, in total, 41 Gore Exclud…

MaleTime FactorsOCCLUSIONmedicine.medical_treatmentSettore MED/22 - Chirurgia VascolareEndovascular aneurysm repairendovascular aneurysm repairAortic aneurysmOcclusionEVARAged 80 and overOUTCOMESmedicine.diagnostic_testGeneral MedicineAnatomyAbdominal aortic aneurysmTreatment OutcomeElective Surgical ProceduresFemaleRadiologyCardiology and Cardiovascular MedicineElective Surgical Proceduremedicine.medical_specialtyAortographyProsthesis DesignAortographyIliac ArteryBlood Vessel Prosthesis Implantationabdominal aortic aneurysm endovascular aneurysm repair Excluder limbs hybrid graft iliac tortuosityabdominal aortic aneurysmBlood vessel prosthesismedicineHumansExcluder limbsRadiology Nuclear Medicine and imagingAgedRetrospective Studiesbusiness.industryENDOVASCULAR REPAIRAORTIC-ANEURYSM REPAIRmedicine.diseaseSurgeryBlood Vessel Prosthesisiliac tortuosityFeasibility StudiesSurgeryhybrid graftSTENT-GRAFTSbusinessTomography X-Ray ComputedAbdominal surgeryAortic Aneurysm AbdominalVascular
researchProduct

Peroperative Intravascular Ultrasound for Endovascular Aneurysm Repair versus Peroperative Angiography: A Pilot Study in Fit Patients with Favorable …

2020

The aim of this study was to compare intravascular ultrasound (IVUS) assistance for endovascular aortic aneurysm repair (EVAR) to standard assistance by angiography.From June 2015 to June 2017, 173 consecutive patients underwent EVAR. In this group, 69 procedures were IVUS-assisted with X-ray exposure limited to completion angiography for safety purposes because an IVUS probe does not yet incorporate a duplex probe (group A), and 104 were angiography-assisted procedures (group B). All IVUS-assisted procedures were performed by vascular surgeons with basic duplex ultrasound (DUS) training. The primary study endpoints were mean radiation dose, duration of fluoroscopy, amount of contrast media…

MaleTime FactorsRadiographymedicine.medical_treatmentContrast MediaPilot Projects030204 cardiovascular system & hematologyRadiography InterventionalEndovascular aneurysm repair030218 nuclear medicine & medical imagingEndovascular aortic repairAortic aneurysmPostoperative Complications0302 clinical medicineRisk FactorsIntravascular ultrasoundAortic aneurysm endovascular repair intravascular ultrasoundFluoroscopyAged 80 and overmedicine.diagnostic_testEndovascular ProceduresAngiographyGeneral MedicineMiddle AgedRadiation ExposureTreatment Outcomesurgical procedures operativecardiovascular systemendovascularFemaleRadiologyCardiology and Cardiovascular MedicineAdultmedicine.medical_specialtyAortographyOperative TimeRadiation DosageAortographyintravascular ultrasoundBlood Vessel Prosthesis Implantation03 medical and health sciencesText miningabdominal aortic aneurysmPredictive Value of TestsmedicineHumanscardiovascular diseasesUltrasonography InterventionalAgedRetrospective StudiesIVUSbusiness.industrymedicine.diseaseAngiographySurgerybusinessAortic Aneurysm AbdominalAbdominal surgeryAnnals of Vascular Surgery
researchProduct

Anastomotic Pseudoaneurysm Complicating Renal Transplantation: Treatment Options

2010

Introduction: Anastomotic pseudoaneurysm following renal transplantation is uncommon. Indications for repair, treatment options and outcomes remain controversial. Report: We present 6 renal transplant recipients with large anastomotic pseudoaneurysms. Five of the patients underwent open repair while one had a stent-grafting and delayed transplant nephrectomy for a ruptured pseudoaneurysm. A transplant nephrectomy was needed in all cases but one. Arterial reconstruction enabled limb salvage in all cases. One patient died of sepsis postoperatively. No patient presented late infection, failure of vascular reconstruction, nor pseudoaneurysm recurrence. Conclusions: Surgical excision of anastomo…

MaleTime FactorsSettore MED/22 - Chirurgia VascolareNephrectomyTransplant nephrectomyPseudoaneurysmRenal ArteryStentTransplantation HomologouMedicine(all)Open repairAnastomosis SurgicalTreatment optionsMiddle AgedBlood Vessel ProsthesiTreatment Outcomesurgical procedures operativecardiovascular systemOpen repairFemaleStentsRadiologyCardiology and Cardiovascular MedicineAneurysm FalseHumanAdultReoperationmedicine.medical_specialtyTime FactorAnastomosisIliac ArterySepsisBlood Vessel Prosthesis ImplantationAneurysmEndovascular repairmedicineHumansTransplantation HomologousStent-graftcardiovascular diseasesAgedbusiness.industryRenal transplantationmedicine.diseaseKidney TransplantationSurgeryBlood Vessel ProsthesisTransplantationSurgerybusinessTomography X-Ray ComputedAneurysm InfectedEuropean Journal of Vascular and Endovascular Surgery
researchProduct

Fenestrated Stent Grafting for Short-necked and Juxtarenal Abdominal Aortic Aneurysm

2010

Objectives: To present an 8-year clinical experience in the endovascular treatment of short-necked and juxtarenal abdominal aortic aneurysm (AAA) with fenestrated stent grafts. Methods: At our tertiary referral centre, all patients treated with fenestrated and branched stent grafts have been enrolled in an investigational device protocol database. Patients with short-necked or juxtarenal AAA managed with fenestrated endovascular aneurysm repair (F-EVAR) between November 2001 and April 2009 were retrospectively reviewed. Patients treated at other hospitals under the supervision of the main author were excluded from the study. Patients treated for suprarenal or thoraco-abdominal aneurysms wer…

MaleTime Factorsmedicine.medical_treatmentShort neckFenestrated graftKaplan-Meier EstimateOPEN REPAIREndovascular aneurysm repairSettore MED/22 - Chirurgia VascolareAortic aneurysmEVARNetherlandsAged 80 and overMedicine(all)medicine.diagnostic_testENDOGRAFT REPAIRMiddle AgedJuxtarenalAbdominal aortic aneurysmProsthesis FailureTreatment OutcomeFemaleKidney DiseasesStentsCardiology and Cardiovascular MedicineReoperationmedicine.medical_specialtyAortographyArterial Occlusive DiseasesFenestrated graftsProsthesis DesignAortographyRisk AssessmentBlood Vessel Prosthesis ImplantationAneurysmRenal DialysisBlood vessel prosthesismedicineHumanscardiovascular diseasesAgedRetrospective Studiesbusiness.industryStentENDOVASCULAR REPAIRmedicine.diseaseAneurysmBlood Vessel ProsthesisSurgeryAbdominal aortic aneurysmSurgerybusinessTomography Spiral ComputedAortic Aneurysm AbdominalAbdominal surgeryEuropean Journal of Vascular and Endovascular Surgery
researchProduct

Renewed endovascular repair for recurrent acute abdominal aortic aneurysm

2008

The aim of the study was to describe the successful endovascular management of a patient who was admitted urgently with a second episode of acute abdominal aortic aneurysm (AAA) 30 months after emergency endovascular abdominal aortic aneurysm repair (eEVAR) for a ruptured AAA. The patient, an 84 year-old male physician, presented with severe acute abdominal and back pain. Contrast-enhanced computer tomography scanning showed type III endoleak owing to complete disconnection of both graft limbs and the prosthetic main body. Treatment consisted of acute stent-grafting with two bridging stent-grafts to seal the endoleak and reline the graft. The patient is alive and well 6 months postoperative…

Malemedicine.medical_specialtyEndoleak type IIIRecurrent acuteSettore MED/22 - Chirurgia VascolareBlood Vessel Prosthesis ImplantationPostoperative ComplicationsRecurrenceEndovascular repairBack painmedicineHumansRadiology Nuclear Medicine and imagingcardiovascular diseasesAcute abdominal aortic aneurysmAged 80 and overEndoleak type IIbusiness.industrymedicine.diseaseAbdominal aortic aneurysmSurgerysurgical procedures operativeTreatment Outcomecardiovascular systemEmergency MedicineRadiologymedicine.symptombusinessTomography X-Ray ComputedAortic Aneurysm Abdominal
researchProduct

Endograft repair of spontaneous infrarenal abdominal aortic dissection

2005

A 71-year-old man with a history of hypertension and a recent myocardial infarction experienced a sudden periumbilical and back pain. Abdominal tenderness was found at physical examination, with no changes in electrocardiogram and serial enzyme determinations. Computed tomographic angiography (CTA) showed a normal thoracic aorta, an infrarenal aortic dissection extending into the left common iliac artery and a contralateral iliac occlusive disease (A, Cover). Although antihypertensive therapy was administered, the patient had persistent pain; subsequently, he underwent endovascular repair with a bifurcated stent graft (Talent, Medtronic Ave, Santa Rosa, Calif) introduced via the left femora…

Malemedicine.medical_specialtymedicine.medical_treatmentDissection (medical)Settore MED/22 - Chirurgia VascolareAneurysm Dissectingmedicine.arteryMedicineThoracic aortaHumanscardiovascular diseasesAgedAortic dissectionbusiness.industryVascular diseaseAbdominal aortaStentendovascular repair aortic dissectionLeft Common Iliac Arterymedicine.diseaseAortic DissectionIntroducer sheathSurgeryRadiologybusinessCardiology and Cardiovascular MedicineVascular Surgical ProceduresHumanAortic Aneurysm AbdominalJournal of Vascular Surgery
researchProduct

External iliac artery pseudoaneurysm complicating renal transplantation

2009

Objective: To assess the etiology, management and outcome of iliac pseudoaneurysms following renal transplantation. Methods: Eleven patients who underwent repair between 1982 and 2007 were identified. Five (Group 1) presented pseudoaneurysm at the anastomosis of the donor renal and native iliac arteries, and six (Group 2) presented iliac pseudoaneurysm following transplant nephrectomy. Intraoperative cultures and immunohistochemical examinations were obtained from all surgical cases to determine the existence of a relationship between infection or transplant rejection and pseudoaneurysm formation. Results: Endovascular repair (EVR) was used to treat three patients, while eight patients unde…

Pulmonary and Respiratory MedicineAdultMaleReoperationmedicine.medical_specialtyTime Factorspseudoaneurysm.medicine.medical_treatmentExternal iliac arteryendovascular repairAnastomosisSettore MED/22 - Chirurgia VascolareIliac ArteryNephrectomyPseudoaneurysmRenal Arterymedicine.arteryiliac artery pseudoaneurysmCandida albicansmedicineEscherichia coliHumanscardiovascular diseasesRenal arteryAgedRetrospective Studiesbusiness.industryAnastomosis SurgicalExternal iliac arteryrenal transplantationMiddle Agedmedicine.diseaseKidney TransplantationNephrectomyopen repairTransplant rejectionTransplantationTreatment Outcomecardiovascular systemEtiologySurgeryFemaleRadiologyCardiology and Cardiovascular MedicinebusinessTomography X-Ray ComputedVascular Surgical ProceduresAneurysm FalseMagnetic Resonance Angiography
researchProduct

Chimney endografting for pararenal aortic pathologies using transfemoral access and the lift technique

2013

Purpose: To present a technique for transfemoral implantation of parallel grafts into the renal arteries in patients with anatomy or morphology that blocks standard antegrade chimney graft delivery. Technique: In a totally percutaneous approach, a 5-F pigtail angiographic catheter is passed into the aorta above the renal arteries via a 0.035-inch hydrophilic guidewire, followed by an 8-F sheath. The target vessel is cannulated with the hydrophilic wire followed by a 5-F reverse curve catheter; the wire is changed for a Rosen wire. The main stent-graft body is delivered and parked at the level of the aortic bifurcation. The Viabahn chimney endograft is advanced ~1 to 2 cm into the target ren…

Settore MED/22 - Chirurgia Vascolareendovascular repair abdominal aorta pararenal aorta aneurysm endovascular aneurysm repair stent-graft chimney graft chimney technique deployment technique self-expanding stent-graft
researchProduct